« Previous
Next »
Journal of Foot and Ankle Surgery
Volume 44, Issue 5
, Pages 336-344
, September 2005
The Effect of Temperature Elevation During Discontinuous Use of Rotatory Burrs in the Correction of Hallux Valgus
References
- . The effect of heat on bone regeneration (an experimental study in the rabbit using the bone growth chamber) . J Oral Maxillofac Surg . 1984;42:705–711
- . Heat caused by drilling cortical bone. Temperature measured in vivo in patients and animals . Acta Orthop Scand . 1984;55:629–631
- . The thermal effects of skeletal fixation-pin insertion in bone . J Bone Joint Surg Am . 1984;66:1077–1083
- . Temperatures measured in human cortical bone when drilling . J Bone Joint Surg Am . 1972;54:297–308
- . An internally cooled saw blade for bone cuts. Lower temperatures in 30 knee arthroplasties . Acta Orthop Scand . 1990;61:321–323
- . Influence of temperature on the compact bone substance during drilling, thread cutting and insertion of bone screws . Z Orthop Ihre Grenzgeb . 1972;110:909–913
- . Temperature changes induced by 809-nm GaA1As laser at the implant-bone interface during simulated surface decontamination . Clin Oral Implants Res . 2003;14:91–96
- . Bone growth around dental implants . Dent Clin North Am . 1999;35:585–601
- . The effect of speed, pressure, and time on bone temperature during the drilling of implant sites . Int J Oral Maxillofac Implants . 1996;11:35–37
- . Temperature changes during high-speed drilling on bone . J Oral Surg Anesth Hosp Dent Serv . 1962;20:475–477
- . Thermal injury from mastoid bone burrs . Ann Otol Rhinol Laryngol . 1978;87:43–49
- . Thermal response and torque resistance of five cortical half-pins under simulated insertion technique . J Orthop Res . 1995;13:615–619
- . The effect of speed, pressure, and time on bone temperature during the drilling of implant sites . Int J Oral Maxillofac Implants . 1996;11:35–37
- . Temperature rise during drilling through bone . Int J Oral Maxillofac Implants . 1997;12:342–353
- . Heat generation during implant site preparation (an in vitro study) . Int J Oral Maxillofac Implants . 1997;12:186–193
- . The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants (a study of drill durability) . Int J Oral Maxillofac Implants . 2004;19:335–349
- . Orthopaedic bone drills-can be improved? Temperature changes near the drilling face . J Bone Joint Surg Br . 1996;78:357–362
- . Heat generation during ulnar osteotomy with microsagittal saw blades . Iowa Orthop J . 2003;23:46–50
- . Influence of different parameters on bone heating and drilling time in implantology . Clin Oral Implants Res . 1997;8:189–197
- . Heat generation during implant drilling (the significance of motor speed) . J Oral Maxillofac Surg . 2002;60:1160–1169
-
.
Future directions in innovative minimally invasive surgery
.
Lancet
. 1999;353(Suppl 1):SI12–SI15
- . Indications and technique of bone cutting . Chirurg . 1998;69:1188–1196
- . Minimal incision surgery . Foot Ankle . 1992;13:157–160
- . Complications in minimal incision surgery . Clin Podiatr Med Surg . 1991;8:221–242
- . The Reverdin-Isham procedure for the correction of hallux abducto valgus. A distal metatarsal osteotomy procedure . Clin Podiatr Med Surg . 1991;8:81–94
-
.
Observations on hallux valgus
.
J Bone Joint Surg Br
. 1951;33:376–391
-
.
Hallux valgus
.
In:
Surgery of the Foot and Ankle
. Mosby: St. Louis, MO; 1999;p. 175
- . The four biomechanical stages of fracture repair . J Bone Joint Surg Am . 1977;59:188–192
- . The Fluoroscan imaging system in foot and ankle surgery . Foot Ankle . 1993;14:545–549
- . Factors affecting heat generation during implant site preparation (a review of biologic observations and future considerations) . Int J Oral Maxillofac Implants . 1999;14:127–136
-
.
Thermal induced bone necrosis in rabbits. Relation to implant failure in humans
.
Clin Orthop Jun
. 1984;186:284–292
- . The temperature dependence of the deformation of bone . J Biomech . 1992;25:11–16
- . The effect of irrigation on osteotomy depth and bur diameter . Int J Oral Maxillofac Implants . 1996;11:634–638
- . Drilling of bone . J Biomech . 1976;9:553–559
- . Thermal injury to bone. A vital-microscopic description of heat effects . Int J Oral Surg . 1982;11:115–121
- . Temperature elevations in orthopaedic cutting operations . J Biomech . 1982;15:267–275
- . Development of raised temperature after osteotomies . J Maxillofac Surg . 1974;2:141–145
- . The influence of active shear or compressive motion on fracture-healing . J Bone Joint Surg Am . 1998;80:868–878
-
.
Complications after surgery of the hallux
.
Clin Orthop Oct
. 2001;391:59–71
The author has no financial interest or conflict of interest in the products used in this study.
PII: S1067-2516(05)00468-0
doi: 10.1053/j.jfas.2005.07.009
© 2005 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Journal of Foot and Ankle Surgery
Volume 44, Issue 5
, Pages 336-344
, September 2005
