Journal of Foot and Ankle Surgery
Volume 45, Issue 1 , Pages 13-19, January 2006

Analysis of Three Types of Fixation of the Weil Osteotomy

  • Craig T. Jex, DPM

      Affiliations

    • Submitted while third-year surgical resident, St. John North Shores Podiatric Surgical Residency Program, Harrison Township, MI
  • ,
  • Chanda J. Wan, DPM

      Affiliations

    • Submitted while second-year surgical resident, St. John North Shores Podiatric Surgical Residency Program, Harrison Township, MI
    • Corresponding Author InformationAddress correspondence to: Chanda J. Wan, DPM, 117 North Braddock St #150, Winchester, VA 22601
  • ,
  • Steve Rundell, MS

      Affiliations

    • Submitted while Graduate Student, College of Engineering, Michigan State University, East Lansing, MI
  • ,
  • Roger C. Haut, PhD

      Affiliations

    • Director, Orthopedic Biomechanics Laboratories, Michigan State University, East Lansing, MI
  • ,
  • Brian MacDonald, DPM (FACFAS)

      Affiliations

    • Chief, Department of Podiatric Surgery, St. John North Shores Hospital, Harrison Township, MI
  • ,
  • Stuart J. Wertheimer, DPM (FACFAS)

      Affiliations

    • Residency Director, St. John North Shores Hospital, Harrison Township, MI

This study assessed 3 methods of fixation for the Weil osteotomy. A total of 40 bone models were divided equally into 4 groups: a control group consisting of intact lesser rays; and Weil osteotomies that were fixated with 2 crossed Kirschner wires (0.045-in K-wires), 2.0-mm cortical screws, or cannulated 2.4-mm cortical screws. Each specimen was stressed in a computer-controlled hydraulic tensile testing machine, and maximum load, energy to failure, and stiffness were recorded. The following mean load to failure measurements were found: control, 62.9 Newtons (N); K-wire, 22.9 N; cannulated screw, 31.3 N; and noncannulated screw, 19.9 N. There was no statistical difference among the 3 groups of fixation methods in terms of the maximum load. The mean energy to failure of the control group was 326 joule (J); K-wire, 79 J; cannulated screw, 163 J; and noncannulated screw, 66 J. The cannulated screw generated a statistically greater amount of energy at failure than the noncannulated screw (P < .05). The mean structural stiffness of the control group was 7.3 N/mm; K-wire, 2.8 N/mm; cannulated screw 3.3 N/mm; and noncannulated screw, 3.2 N/mm. There was no statistical difference in structural stiffness among the 3 groups of fixation methods. The results indicated a trend toward better biomechanical stability with the 2.4-mm cannulated screw than the 2.0-mm noncannulated screw for fixation of the Weil osteotomy.

Key words:  Weil osteotomy , metatarsal osteotomy , lesser metatarsalgia , screw fixation

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 25.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 None of the authors received any financial assistance and had no conflict of interest with regards to the products mentioned in this study.

PII: S1067-2516(05)00652-6

doi:10.1053/j.jfas.2005.10.007

Journal of Foot and Ankle Surgery
Volume 45, Issue 1 , Pages 13-19, January 2006